Order Code
H3DT-HCL 100 to 120 VAC
Dimensions (Unit: mm)
Terminal Arrangement
17.5
100
90
86
90
Front
5
Side view
Technical criteria
Rated supply voltage
Operating mode
Input method
Minimum power-ON time
Control Output
Accuracy of operating time
Setting error
Operating Temperature
Operating Humidity
IP
100 to 120 VAC, 50/60 Hz
OFF delay
None
0.3 s
5 A at 250 VAC with resistive load (cosφ = 1),
5 A at 30 VDC with resistive load
±1% of FS max.
±10% of FS ±0.05 s max.
−20 to 60°C
25% to 85%
IP30 (Terminal block: IP20)
For the most recent information on models that have been certified for safety standards, refer to your OMRON website.
Nomenclature
2
1
1
2
3
3
Power indicator
Time range switch
Main dial
Time range
Time range setting
Set time range
Power ON time
Scale numbers
x1
1 to 12 s
x10
10 to 120 s
0.3 s min.
12
Timing Chart
OFF Delay
Note: Refer to the official Datasheet, how to use Gate input.
Accessories
Front Cover
Y92A-D1A